A. Surface mounted fixed to grid system
This solution is applicable for heavy lights (services) weighing >5 kg. It allows the transfer of the load directly to the soffit via the grid system using ERICO iDS clips. The maximum load on the clip should not exceed 25 Kg.

-
B. Surface mounted direct fixed to soffit System B, C, G and Cosmos
Fasten light by direct fixing through tile to soffit.

-
C. Sliding T-head bolt in System RockLink Integra
Fasten spotlight or similar accesory using sliding T-head bolt. The maximum load per bolt should not exceed 5 Kg.

-
D. Spotlight integrated with yoke
This solution is applicable for spotlights (services) weighing <=0.25 kg. Cut hole in tile to match size and shape of light. Use small metal yoke to spread load on to back of tile. Fit light into tile and yoke.

-
E. Downlight integrated with yoke
This solution is applicable for lights (services) weighing<= 3 kg. Cut hole in tile and centre of yoke to match size and shape of light. If using "out of balance" light ( as shown), ensure overhang is in line with length of yoke. Fit light into tile and yoke.

-
F. Downlight integrated with support arms
This solution is applicable for lights (service) weighing ¡ >=0.25 kg. Support light using two support arms, supported on bulb of grid components. Cut hole in the tile to match size and shape of light. If using "out of balance" light (as shown), ensure overhang is in line with support arms.

-
G. Downlight independently suspended
This solution is applicable for lights (services) weighing> 3 kg. Cut hole in tile to match size and shape of light. Independently suspend light, making it stable and well balanced.

-
H. Uplight suspended from grid system
This solution is applicable for lights (services) weighing < 5 kg. Connect light to grid using appropriate ERICO Caddy clip.

-
I. Recessed modular in System RockLink 24 FasTrac, RockLink 24, RockLink 15, RockLink Intregra
Support fittings on a a minumum of two opposite sides on bulb of grid components.

-
J. Recessed modular in RockLink System Z
Support fittings on a minimum of two opposite sides on top of Z sections or mainrunners (primary channels). Ensure proposed fitting body size is compatible with RockLink System Z.

-
K. Surface mounted lighting track
Connect lighting track to grid using suitable clip from light manufacturer.