Rockfon® Bass Plus

A complementary acoustic solution that is ideal for areas that require sound absorption for low frequencies, between 125 Hz & 250 Hz, such as classrooms
Back
Back

Sound absorption details

Practical Sound Absorption Coefficient (αp)
Thickness Suspension height 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz Sound absorption class αw NRC
50mm 200mm 0.70 0.85 1.00 1.00 1.00 1.00 A 1.00 1.00
50mm 200mm 0.70 0.90 1.00 1.00 1.00 1.00 A 1.00 1.00

Sound absorption is measured in accordance with ISO 354.

Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Back
Sound curve
Back
Sound curve

Other performances

Compare
Reaction To Fire Reaction To Fire A1
Reaction to fire is classified in accordance with EN 13501-1.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment Environment Fully recyclable stone wool
Thermal Insulation Thermal Insulation Thermal conductivity: λD = 40 mW/mK
Thermal resistance: 50 mm R = 1.25 m2K/W
The thermal conductivity of products with a thickness ≥ 30mm is measured in accordance with EN 12667 and expressed in mW/mK. Thermal resistance is expressed in m²K/W.
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
The thermal conductivity of products with a thickness ≥ 30mm is measured in accordance with EN 12667 and expressed in mW/mK. Thermal resistance is expressed in m²K/W.
Back

Full range

Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
1200 x 600 50 2.70 0

Sound absorption details

αw 1.00
NRC 1.00
Sound absorption class A

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 8
Area Per Pack 5.76 m2
Back

Sound absorption details

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 8
Area Per Pack 5.76 m2
Back

Downloads

documents

 

 

pdf
Rockfon® Bass Plus | Datasheet
Rockfon® Bass Plus | Datasheet

pdf
DoP-RFN-1174-N861-2 - Rockfon® Bass Plus
DoP-RFN-1174-N861-2 - Rockfon® Bass Plus

pdf
Back