Rockfon VertiQ® wall panel

Attractive and impact resistant, highly sound-absorbent acoustic wall panels (Class A) suitable for class rooms, sports activity areas and offices
Order Sample
Back

Colour

Colour group

All
All
Greys & Blacks
Whites

White

ColourWhite
Colour groupWhites
NCSNCS S 0500-N
Light reflection72

Order Sample

Quantity:
1

Edge

Select an edge
Select an edge
C
White

Stone wool tile

White

NCS S 0500-N

72 % Light reflection

More Info

Order Sample

Quantity:
1

Edge

Select an edge
Select an edge
C
White
Lightgrey
Grey
Black

Case studies featuring Rockfon VertiQ® wall panel

1/23
Back

Sound absorption details

Practical Sound Absorption Coefficient (αp)
Edge Thickness Suspension height 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz Sound absorption class αw NRC
C, A HAT, A24 40mm 40mm 0.25 0.75 1.00 1.00 1.00 1.00 A 1.00 1.00

Sound absorption is measured in accordance with ISO 354.

Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Back
Sound curve

Other performances

Compare
Reaction To Fire Reaction To Fire A2-s1,d0 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Light reflection and light diffusion Light reflection and light diffusion White 72% Lightgrey 61% Grey 33% Black 5%
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Cleaning Cleaning Vacuum
Vacuum: The surface can be vacuum cleaned with a soft brush attachment.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment Environment Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Impact Resistance Impact Resistance Rockfon VertiQ C mounted in Rockfon System VertiQ C Wall has been tested for impact resistance in accordance with DIN 18032 part 3 and fulfils the demands for handball ball throwing (restrictedly safe against ball throwing).
Rockfon VertiQ A mounted in Rockfon System VertiQ HAT A Wall has been tested for impact resistance in accordance with DIN 18032 part 3 and fulfils the demands for handball ball throwing (restrictedly safe against ball throwing).
Rockfon System VertiQ HAT A Wall gives additional protection of Rockfon VertiQ A panels by HAT steel profile and can be used in areas subjected to occasional impact.
The impact resistance of Rockfon System VertiQ HAT A Wall and Rockfon System VertiQ C Wall is high, however, it is not recommended for use in areas which are subjected to continuous high levels of impact.
The woven surface of Rockfon VertiQ panels provides enhanced resistance to perforation, tested in accordance with NF P 08-301.,
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Vacuum: The surface can be vacuum cleaned with a soft brush attachment.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back
Back

Full range

Edge Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
A HAT 1200 x 1200 40 5.20 43 Rockfon® System VertiQ® HAT A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall panels with sound absorption properties

Sound absorption details

αw 1.00
NRC 1.00
Sound absorption class A

Tile details

Minimum installation height 43 mm

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
A HAT 2700 x 1200 40 5.20 43 Rockfon® System VertiQ® HAT A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall panels with sound absorption properties

Sound absorption details

αw 1.00
NRC 1.00
Sound absorption class A

Tile details

Minimum installation height 43 mm

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
A24 1200 x 1200 40 5.20 43 Rockfon® System VertiQ® T24 A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound absorption details

αw 1.00
NRC 1.00
Sound absorption class A

Tile details

Minimum installation height 43 mm

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
A24 2700 x 1200 40 5.20 43 Rockfon® System VertiQ® T24 A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound absorption details

αw 1.00
NRC 1.00
Sound absorption class A

Tile details

Minimum installation height 43 mm

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
C 2400 x 600 40 6.40 43 Rockfon® System VertiQ® C Wall™

Recommended installation system

Concealed wall system Rockfon® System VertiQ® C Wall™ Wall panels with sound absorption and impact resistance properties

Sound absorption details

αw 1.00
NRC 1.00
Sound absorption class A

Tile details

Minimum installation height 43 mm

Packaging

Pieces Per Pack 4
Area Per Pack 5.76 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall panels with sound absorption properties

Sound absorption details

Tile details

Minimum installation height 43 mm
Easy access -

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall panels with sound absorption properties

Sound absorption details

Tile details

Minimum installation height 43 mm
Easy access -

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound absorption details

Tile details

Minimum installation height 43 mm
Easy access -

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound absorption details

Tile details

Minimum installation height 43 mm
Easy access -

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
Back

Recommended installation system

Concealed wall system Rockfon® System VertiQ® C Wall™ Wall panels with sound absorption and impact resistance properties

Sound absorption details

Tile details

Minimum installation height 43 mm
Easy access -

Packaging

Pieces Per Pack 4
Area Per Pack 5.76 m2
Back

Downloads

documents

 

 

dwg pdf
A-edge | CAD
A-edge | CAD

dwg
pdf
C-edge installed using hooks - concealed c channel | CAD
C-edge installed using hooks - concealed c channel | CAD

dwg
pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
Rockfon VertiQ® wall panel | Datasheet
Rockfon VertiQ® wall panel | Datasheet

pdf
DoP-RFN-0129-041-4 - Rockfon VertiQ® wall panel
DoP-RFN-0129-041-4 - Rockfon VertiQ® wall panel

pdf
Rockfon® System VertiQ® HAT A Wall | Installation Guide
Rockfon® System VertiQ® HAT A Wall | Installation Guide

pdf
pdf
Rockfon® System VertiQ® T24 A Wall | Installation Guide
Rockfon® System VertiQ® T24 A Wall | Installation Guide

pdf
pdf
Rockfon® System VertiQ® C Wall™ | Installation Guide
Rockfon® System VertiQ® C Wall™ | Installation Guide

pdf
icon
Design for Schools | Education Guide
Design for Schools | Education Guide

Schools How acoustic solutions make a difference to focus and wellbeing in schools.

pdf
icon
Rawlins Academy Activity Centre | Education case study
Rawlins Academy Activity Centre | Education case study

The former swimming pool was converted into a multi-use fitness studio and activity space. To help create a healthy acoustic environment, Rockfon VertiQ A wall panels and Rockfon Eclipse ceiling islands were installed throughout.

pdf
Back