Rockfon® Soundstop

Acoustic barriers which reduce noise transfer in ceiling and floor plenums
Back
Back

Other performances

Compare
Direct Sound Insulation Direct Sound Insulation Rw = 30
Sound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.
Reaction To Fire Reaction To Fire A1 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment Environment Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Back
Sound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back

Full range

Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
1200 x 600 60 6.90 0

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack
Area Per Pack m2

* Dimensions given correspond exactly to the size of the finished products, two thickness's of 30mm arrive at the finished thickness of 60mm.

Back

Sound absorption details

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack
Area Per Pack m2
Back

Downloads

documents

 

 

pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
Rockfon® Soundstop | Datasheet
Rockfon® Soundstop | Datasheet

pdf
DoP-RFN-0012-R003-A1-01 - Rockfon® Soundstop
DoP-RFN-0012-R003-A1-01 - Rockfon® Soundstop

pdf
Back